The most important elevator safety tips are to check the car's alignment with the landing, stay clear of closing doors, respect the rated load limit, and know how to call for help if the elevator stops unexpectedly.

Passengers can reduce everyday risks by following these precautions. Building owners and managers must also address equipment maintenance, safety inspections, and emergency response arrangements.

This guide covers safe riding practices, emergency procedures, warning signs of elevator malfunctions, and safety considerations for building owners.

6 Essential Elevator Safety Tips for Passengers

elevator-passenger-safety-tips 

Check the landing, use the door-open button, and keep clear of closing doors.

1. Check the Landing Before Entering or Exiting

Allow passengers to leave the elevator before boarding. Make sure the car is present and its floor is aligned with the landing.

An unexpected height difference can create a tripping hazard, particularly for older adults and people using wheelchairs or mobility aids.

Pay attention to the gap at the doorway. If the car stops noticeably above or below the landing, do not cross the threshold. Report the problem and request assistance if necessary.

2. Keep Clear of Closing Doors

Use the door-open button when someone needs more time to enter or exit. Never try to hold closing elevator doors with your hands, feet, luggage, or other objects.

Door protection systems are designed to reduce contact and entrapment hazards, but their detection capabilities vary. Thin items, such as bag straps and pet leashes, may not be reliably detected by every system.

Keep loose clothing and personal belongings clear of the doorway. If the doors are closing, wait for the next elevator rather than rushing inside.

3. Respect the Rated Load Limit

Check the rated capacity displayed inside the elevator car. The total load includes passengers, luggage, and any other items being transported.

If an overload warning activates, some passengers or items must be removed before the journey continues. Do not attempt to bypass the warning or force an overloaded elevator to operate.

When the car is crowded, wait for another elevator.

4. Maintain Your Balance During the Ride

Stand away from the doors and use the handrail for support if needed.

Avoid jumping, running, pushing, or playing inside the car. These activities can cause passengers to lose their balance or interfere with normal elevator operation.

Keep enough space around the entrance for other passengers to board and exit safely.

5. Supervise Children and Assist Passengers When Needed

Children should ride with responsible adult supervision. Teach them to stay clear of the doors, use the controls appropriately, and remain inside the car if it stops unexpectedly.

Allow additional boarding and exiting time for passengers with limited mobility. Use the door-open button rather than blocking the doorway.

Offer assistance when appropriate, while respecting each passenger's independence and mobility needs.

6. Report Elevator Problems Promptly

Repeated door failures, unexpected movement, unusual mechanical noises, or persistent leveling problems should be reported to building management.

When possible, provide the elevator identification number, the affected floor, and a description of the incident.

Avoid further use of an elevator with a suspected safety-related malfunction until qualified personnel have assessed its condition.

Passengers should not attempt repairs, reset equipment, or interfere with elevator safety devices.

What to Do If You Get Stuck in an Elevator

An elevator can stop unexpectedly because of a power interruption, equipment fault, or protective system activation. A stopped elevator does not, by itself, indicate that the car is about to fall.

stuck-in-elevator-emergency-safety 

Use the available emergency communication equipment and wait for trained responders.

If you become trapped:

1. Stay inside the car. Remain calm and move away from the doors.

2. Call for assistance. Use the emergency call button, alarm, intercom, or telephone provided.

3. Explain the situation. If contact is established, provide your location, elevator identification number, number of passengers, and any urgent medical concerns.

4. Use another communication method if needed. If the emergency communication equipment fails to establish contact, use a mobile phone where reception is available to contact building management or local emergency services.

5. Wait for authorized rescue personnel. Follow their instructions and exit only when they confirm that it is safe.

Do not force the doors open, climb out between floors, or attempt to escape through the ceiling. Unexpected car movement and exposure to the hoistway can create serious fall and crushing hazards.

If anyone experiences a medical emergency, or if there is smoke, fire, or another immediate threat, contact local emergency services as soon as possible.

See the NYC Department of Buildings elevator safety guidance for further passenger safety advice.

Elevator Safety During Fire, Power Outages, and Earthquakes

Emergency procedures depend on the nature of the incident, the elevator's design, and the building's emergency response plan.

During a Fire

Do not use ordinary passenger elevators to evacuate a building during a fire. Follow the designated evacuation routes and instructions from emergency personnel.

Some buildings have specially designed occupant evacuation elevators. These are exceptions and should be used only in accordance with the building's approved evacuation procedures.

People who cannot use stairs should follow the building's accessible evacuation arrangements and request assistance when necessary.

If you are already inside an elevator, follow emergency instructions and leave at a safe landing when possible. If the elevator stops and you cannot exit safely, call for emergency assistance.

For workplace evacuation planning in the United States, consult OSHA emergency preparedness guidance.

During a Power Outage

Some elevators have automatic rescue devices or emergency power arrangements that support passenger evacuation during certain power interruptions.

These functions are not identical across elevator systems. Do not assume that every elevator will automatically reach a landing when the power fails.

If you become trapped, use the available emergency communication equipment and wait for assistance.

Resume using elevators affected by the outage only when building management confirms that they are available for normal operation.

During an Earthquake

Avoid entering elevators during an earthquake.

If you are already inside one, follow the building's emergency instructions and leave at the first safe landing where the car stops and the doors open normally.

If the elevator becomes immobilized, use its emergency call system and wait for rescue.

After an earthquake, follow building management instructions before using elevators that may have been affected. Restored electrical power alone does not establish that the equipment is safe to operate.

For location-specific advice, see the earthquake safety guidance for travelers in Japan.

Elevator Safety Checklist for Building Owners and Managers

Building owners and managers play an important role in maintaining elevator safety throughout the equipment's service life.

The following checklist provides general management considerations. Specific obligations depend on local regulations, equipment type, and building use.

Arrange Preventive Maintenance

Establish a maintenance program with an appropriately qualified elevator service provider.

The program should account for equipment age, usage, operating conditions, manufacturer recommendations, and applicable regulations.

Maintenance should address relevant systems, including doors, leveling performance, controls, drive equipment, emergency communication, and protective devices.

A high-traffic commercial elevator may require a different maintenance schedule from a low-traffic residential installation.

For more guidance on maintenance planning and equipment care, see our guide to commercial elevator maintenance.

Complete Required Inspections and Safety Tests

Preventive maintenance and regulatory inspections serve different purposes. Maintenance addresses equipment condition, while required inspections and tests assess compliance with applicable safety requirements.

Confirm the inspection intervals, testing requirements, personnel qualifications, operating permits, and documentation required in your jurisdiction.

Routine servicing does not replace statutory inspections or required safety tests.

For an example of regional regulatory guidance, see the Cal/OSHA elevator owner resources for California.

Establish Emergency Communication and Rescue Procedures

Maintain emergency communication equipment and verify how calls from trapped passengers are received and handled.

Ensure that designated building personnel know whom to contact, how to communicate with passengers, and when emergency services are needed.

Emergency arrangements should also address communication failures, medical emergencies, and accessibility needs.

Building staff must not carry out unauthorized passenger extraction or enter restricted elevator equipment areas.

Maintain Safe and Accessible Entrances

Keep elevator entrances adequately illuminated and free from obstructions, loose materials, and slippery surfaces.

Make sure required operating instructions, capacity information, and emergency contact details remain legible.

Address damaged entrances, recurring leveling problems, and accessibility concerns promptly.

Record Faults and Manage Unsafe Equipment

Maintain records of reported faults, servicing, inspections, repairs, and corrective actions.

Repeated faults should be investigated rather than treated as unrelated incidents.

When a safety-related malfunction is suspected, restrict access and arrange an assessment. Equipment that is unsafe must remain out of service until the necessary corrective work and applicable return-to-service procedures have been completed.

Access to elevator hoistways, pits, machine rooms, and other restricted equipment areas must be limited to authorized personnel with the appropriate qualifications.

Safety Features to Consider When Choosing an Elevator

When selecting passenger elevators for a new installation or modernization project, consider the building's intended use, accessibility needs, and applicable safety requirements.

Important configuration considerations include:

• Door protection and locking systems: Protective devices and locking arrangements appropriate to the elevator design.

• Movement and braking protection: Safety systems selected according to the equipment type and applicable requirements.

• Load monitoring: Rated capacity and applicable overload protection functions.

• Emergency communication and lighting: Provisions for requesting assistance and maintaining necessary illumination during emergencies.

• Emergency rescue and power arrangements: Functions available during specified power interruption conditions.

• Leveling performance and accessibility: Entrance and car configurations suitable for the intended passengers.

Before ordering an elevator, confirm which features are included, which are optional, and which are required by the regulations applicable to your project.

Equipment selection, installation, commissioning, inspections, and ongoing maintenance all contribute to safe elevator operation. No individual protective feature can replace these responsibilities.

Planning a New Elevator for Your Building?

Share your specifications with Delfar Elevator to discuss suitable commercial elevator systems and project-specific safety requirements.

Discuss Your Elevator Requirements

Frequently Asked Questions

Are elevators safe for children and older adults?

Properly maintained and operated elevators provide accessible transportation for passengers of different ages and mobility levels.

Children require appropriate supervision. Older adults and passengers using mobility aids should pay particular attention to landing alignment, doorway clearance, and balance during boarding and exiting.

Is regular elevator maintenance the same as a safety inspection?

No. Maintenance focuses on equipment condition and servicing, while regulatory inspections evaluate compliance with applicable requirements.

Building owners should arrange both activities according to local regulations and equipment-specific needs. Completing routine maintenance does not remove the obligation to complete required inspections and safety tests.

What information should building owners request when purchasing an elevator?

Request documented equipment specifications, applicable safety standards, safety device configurations, emergency operating functions, and installation and maintenance requirements.

Confirm that the proposed equipment is suitable for the building's intended use and the regulations that apply at the installation location.

Does emergency power mean an elevator can continue operating normally?

Not necessarily. Some systems provide sufficient backup power for a limited rescue operation, while others support designated elevator service during a power interruption.

The actual operating capability depends on the elevator configuration, backup power arrangement, and building design. Buyers and building owners should verify these functions rather than assume uninterrupted operation.


Add : No.777, Tengfei Road, Zhili, Wuxing, Huzhou, Zhejiang, China.
Tel : +86-572-2235922
Mobile Phone : +86-13511261762
Fax : +86-572-2235912
WhatsApp : +86-13511261762
Skype : bensonelevator
E-mail :  delfar@delfar.cn
               bensonelevator@gmail.com
Contact Us

Useful Links

Home

Delfar Elevator Co., Ltd.

Delfar elevator will continue to adhere its value” mutually-beneficial and win-win cooperation” and business idea” honest management, continuous progress to dedicate to society”, wholeheartedly provide customers with perfect transport and services, becoming a reliable partner with customers. 
Add : No.777, Tengfei Road, Zhili, Huzhou, Zhejiang, China. 
Tel : +86-572-2235922
Mobile Phone : +86-13511261762
Fax : +86-572-2235912
WhatsApp : +86-13511261762
Skype : bensonelevator 
Copyright  2025 Delfar Elevator Co., Ltd.   |   Sitemap    Powed by lanmigo.com